Siemens XT55 manual Commands build in the alarm function, Command for internal test

Models: XT55

1 20
Download 20 pages 3.45 Kb
Page 17
Image 17

XT55 AVL Software Instructions User’s Guide Confidential/Preliminary

s

mobile

$PSRF112, value, *XX

Parameter description:

value: //configure history function

Defined values

1 //enables history

2 //disables history

*XX

//CheckSum has to be calculated.

Example 1:

$PSRF112,1*38

This command enables the history function. The module XT55 records every 180 seconds if the vehicle is driving faster than 10 km/h.

The settings 180 sec. and 10km/h are predefined parameters.

Example 2:

$PSRF112,2*3B

This command disables the history function. No data will be saved in the history.

Commands build in the alarm function

$PSRF112, value, key_number, phone_number *XX

Parameter description:

 

 

value:

//configure the download procedure

 

Defined values

 

10

//enables key configuration

 

11

//disables key configuration

 

12

//displays key number

key_number

//determine the alarm key (1,2 possible)

phone_number

//set the authorized telephone number

*XX

//CheckSum has to be calculated.

Example 1:

$PSRF112,10,2,012345678 *02

This command enables key configuration as well the predefined RMC protocol is send to the authorized telephone number (012345678) in case of an alarm on the key 2.

Example 2:

$PSRF112,11,2*17

This command disables the key (2) configuration.

Example 3:

$PSRF112,12,2*14

This command displays the settings of given key number (2).

The received format is: $alarm key (2): phone: 012345678, protocol: RMC

Command for internal test

$PSRF111,

Parameter description:

value,

value:

//commands overview

*XX

 

Defined value

 

 

 

 

0 //overview of all implemented test commands

 

*XX

//CheckSum has to be calculated.

Example 1:

$PSRF111,0*3A

XT55_avl_ug_V01

Page 17 of 20

15.03.2004

Page 17
Image 17
Siemens XT55 manual Commands build in the alarm function, Command for internal test