INSTALLATION

1.Install the pump on a hard level surface. Make sure that the pump cannot pick up rocks, mud and debris, etc. If neccesary, put a block under the pump to raise it slightly. See Figure 1.

GFCI

Use foliage to cover

tubing to waterfall

Outlet

 

 

 

 

 

 

 

Power INSTALLATIONFigure 2: Adapter connections.OPERATION cord Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Plastic tubing

to Manual backgroundwaterfall

Landscaping rocks

Raise the pump off of the bottom of the pond

3388 0399 NOC 6030

Figure 1: Typical garden pond and waterfall installation.

2.Protect the power cord from damage. Uncovered cords should be routinely inspected for damage or deterioration. DO NOT operate the pump if the cord is damaged.

3.Choose an adapter and install it as indicated in Figure 2.

Manual backgroundManual background 1-1/4" FNPT X 3/4"

Garden Hose Fitting

1-1/4" X 1-1/4" Hose Barb Elbow

Figure 2: Adapter connections.

OPERATION

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Hazardous voltage. Can shock, burn or cause death. Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.

1.The shaft seal depends on water for lubrication. Do not operate the pump unless it is in water as the seal may be damaged if allowed to run dry.

2.The motor is equipped with an automatic reset ther- mal protector. If the temperature in the motor should rise unduly, the switch will cut off all power before damage can be done to the motor. When the motor has cooled sufficiently, the switch will reset automati- cally and restart the motor. If the protector trips repeatedly, remove the pump and check it as to the cause of difficulty. Low voltage, long extension cords, clogged impeller, very low head or lift, etc., could cause cycling.

3.The pump will not remove all water. If the pump is operating and suddenly no water comes out of the discharge hose, shut off the unit immediately. The water level is probably very low and the unit has bro- ken prime.

NOTICE: For continuous operation, water must flow through pump to prevent motor overheating. The pump is cooled by the water flow through the housing.

4.This pump is designed to pump cold water only. Pumping heated liquids can overheat the motor and cause the thermal overload to trip.

5.Pump can run when water doesn’t completely cover the motor housing, but the inlet must be completely submerged or it will break suction, will not move any water, and may damage the shaft seal.

NOTICE: For continuous operation the water depth must be at least 5” (13 cm) to prevent the pump from overheating.

6.Keep the pump inlet clean at all times. If the ground bottom or surface where the pump sits is dirty, raise the pump slightly to reduce the amount of debris pulled into the pump inlet.

7.If you need to reduce the flow, restrict the discharge. Do not restrict the intake. Doing so will starve the pump for water and can cause overheating.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867