Maintenance

Maintenance

6

MAINTENANCE

MAINTENANCETroubleshootingManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Risk of electric shock. Can burn or cause death. Disconnect the power before servicing, repairing, or working on pump.

The pump’s motor is completely sealed in the motor housing and does not require any service. Disassembly of the motor housing or modification or removal of the power cord voids the warranty. The power cord is non- replaceable.

Never run the pump dry! Running the pump dry can damage the seal, causing leakage. This pump is a sub- mersible type and must be in water at all times for prop- er operation and cooling.

Periodically clean the pump inlet. This will avoid impeller rotation being hampered by any debris.

To Clean Inlet/Impeller

1.Unplug pump.

2.Remove baseplate by turning in direction of OPEN arrow. Clean out inlet.

3.Remove screw holding volute base to pump housing.

4.Turn volute base in direction of OPEN arrow and remove. Clean out impeller.

To reinstall, reverse above directions. Be sure to replace O-Ring and engage volute base tabs with pump housing before replacing screw.

Troubleshooting

NOTICE: This pump has no serviceable parts inside the motor housing. Opening the motor housing will ruin the pump. If obstructions or blockages of the impeller cannot be cleaned out as described above, or by backflushing into the discharge with a garden hose, replace the pump.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Hazardous voltage; can shock, burn or kill. Unplug the pump before attempting to clean or work on the pump.

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t

Blown fuse or circuit breaker has tripped

If blown, replace with fuse of proper size or reset circuit breaker

start or run

Low line voltage

If voltage under recommended minimum, check size of wiring from main

 

 

switch on property. If OK, contact power company or hydro authority

 

Defective motor

Replace pump

 

 

 

Pump operates but

Low line voltage

If voltage under recommended minimum, check size of wiring from main

delivers little or no

 

switch on property. If OK, contact power company or hydro authority.

water

Something caught in impeller

Cleanout or replace pump

 

Worn or defective parts

Replace pump

 

Check valve installed without

Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump discharge

 

vent hole

& check valve. Drilled hole must be located below the waterline.

 

 

 

Intermittent running

Thermal overload has tripped

Protect the installation from the sun

or pump stopped

 

Pump cooler water

automatically

 

Pump has run dry; add water

 

 

 

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867