Simer Pumps 2945 Specifications and Safety, Description, Performance, General Safety Information

Models: 2943 2945 2956 2958

1 20
Download 20 pages 6.74 Kb
Page 2
Image 2
Specifications and Safety

Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home sumps. Unit is equipped with a 3-prong grounding-type power cord. Shaded-pole motor is oil filled and sealed for cooler running. Sleeve bearings on motor shaft never need lubrication. Automatic reset thermal protection. Not designed for use as a swimming pool drainer.

SPECIFICATIONS

Power supply required

...........................115V, 60 HZ.

Liquid Temp. Range

32°F to 70°F(0°-21°C)

Individual Branch Circuit Required (min.) ....15 Amps

Discharge:

 

Plastic Models

1-1/4" FNPT / 1-1/2" MNPT

Cast Iron Models

1-1/2" FNPT

NOTICE: Do not reduce size of discharge pipe or hose below 1-1/4” diameter. If discharge is too small, pump will overheat and fail prematurely.

Pump water only with this pump.

NOTICE: This unit is not designed as a waterfall or foun- tain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty.

Do not use where water recirculates.

Not designed for use as a swimming pool drainer.

PERFORMANCE

GPH (LPH) AT TOTAL FEET (M) OF LIFT

 

 

5

10

15

No flow

Model

HP

(1.5m)

(3m)

(4.6m)

at height

shown

 

 

 

 

 

 

CAPACITY GALLONS(L)/HOUR

 

below

 

 

 

 

 

2943

1/3

2760

2160

1410

20 Ft.

(10 448)

(8 176)

(5 337)

(6.1M)

 

 

 

 

 

 

 

 

2956

1/3

2800

2200

1400

20 Ft.

(10 599)

(8328)

(5299)

(6.1M)

 

 

 

 

 

 

 

 

2945

1/2

3200

2700

2000

24 Ft.

2958

(12 113)

(10 220)

(7 571)

(7.3M)

 

 

 

 

 

 

 

ELECTRICAL & SWITCH SPECIFICATIONS

 

 

 

Individual

 

 

 

 

Motor

Branch

*Switch Setting

 

 

Full Load

Circuit

in inches (mm)

Model

HP

Amps

Req.(Amps)

On

Off

2943

1/3

9.0

15

13"(330)

6"(152)

2945

1/2

5.5

15

13"(330)

6"(152)

2956

1/3

9.0

15

8"(203)

3"(102)

2958

1/2

6.0

15

8"(203)

3"(102)

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many years of trouble-free service when correctly installed, maintained, and used. However, unusual circumstances (interruption of power to the pump, dirt/debris in the sump, flooding that exceeds the pump’s capacity, electrical or mechanical failure in the pump, etc.) may prevent your pump from func- tioning normally. To prevent possible water damage due to flooding, consult your retailer about a sec- ondary AC sump pump, a DC backup sump pump, and/or a high water alarm. See the “Troubleshooting Chart” in this manual for information about common sump pump problems and remedies. For more infor- mation, see your retailer or call customer service at 1-800-468-7867.

1.Know the pump application, limitations, and potential hazards.

2.Do not use in water with fish present. If any oil leaks out of the motor it can kill fish.

3.Disconnect power before servicing.

4.Release all pressure within system before servic- ing any component.

5.Drain all water from system before servicing.

6.Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.

7.Check hoses for weak or worn condition before each use, making certain that all connections are secure.

8.Periodically inspect sump, pump and system components. Keep free of debris and foreign objects. Perform routine maintenance as required.

9.Provide means of pressure relief for pumps whose discharge line can be shut-off or obstructed.

10.Personal Safety:

a.Wear safety glasses at all times when working with pumps.

b.Keep work area clean, uncluttered and prop- erly lighted – replace all unused tools and equipment.

c.Keep visitors at a safe distance from work area.

d.Make workshop child-proof – with padlocks, master switches, and by removing starter keys.

11.When wiring an electrically driven pump, follow all electrical and safety codes that apply.

12.This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Page 2
Image 2
Simer Pumps 2945, 2958, 2956, 2943 Specifications and Safety, Description, Performance, General Safety Information