Safety

Safety

2

READ AND FOLLOW

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this

READ AND FOLLOW symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.

GENERAL SAFETYELECTRICAL SAFETYManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background warns about hazards that will cause serious personal injury, death or major property damage if ignored.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background warns about hazards that can cause serious personal injury, death or major property damage if ignored.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background warns about hazards that will or can cause minor personal injury or property damage if ignored.

The label NOTICE indicates special instructions which are important but not related to hazards.

Carefully read and follow all safety instructions in this manual and on pump.

Keep safety labels in good condition.

Replace missing or damaged safety labels.

Make workshops childproof; use padlocks and master switches; remove starter keys.

GENERAL SAFETY

1.To avoid risk of serious bodily injury and property damage, read the safety instructions carefully before installing this pump.

2.Follow local and/or national plumbing, building and electrical codes when installing the pump. Use rigid pipe when installing this pump.

3.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Hazardous Pressure. The pump body may explode if used to boost pressure above 100 psi (689 kPa). Do not use this pump with inlet pressure greater than 50 psi (345 kPa). If not already in the plumbing system, install a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi (689 kPa). If local code requires installation of a pressure relief valve capable of handling the full pump flow at a pressure less than 100 psi (689 kPa), follow the code requirements.

4.A low pressure safety cutoff switch is recommended to shut off power to the pump in case of low dis- charge pressure due to interruption of the incoming water supply, broken pipe, etc.

5.Never run the pump dry. To do so can damage inter- nal parts, overheat pump (which can cause burns to people handling or servicing pump), and will void warranty.

6.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Risk of fire or explosion. To avoid risk of fire and explosion, Pump Water Only with this pump. Do not pump flammable liquids or chemicals. Do not use the pump near gas pilot lights or where chemical or gas fumes are present. Use of an electric pump with liquids other than water or in an atmos- phere containing chemical or gas fumes may ignite those liquids or gases and cause injury or death due to an explosion and/or fire.

7.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Burn Hazard. If water is trapped in the pump during operation it may turn to steam. Trapped steam can lead to an explosion and burns. Never run the pump with the outlet closed or obstructed.

8.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Do not touch an operating motor. Modern motors can operate at high temperatures. To avoid burns when servicing the pump, allow it to cool for 20 minutes after shut-down before handling.

ELECTRICAL SAFETY

The pump is supplied with a 3-conductor grounding type cord. Connect only to a properly grounded,

GFCI protected outlet. Do not lift the pump by the elec- trical cord.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Hazardous voltage. Can shock, burn or cause death. Ground the pump before connecting to a power supply. Disconnect the power before working on the pump, motor or tank.

The pump and controller are non-submersible. Keep the motor dry at all times. Do not wash the

motor. Do not immerse. Protect the motor from wet weather.

If using an extension cord, use only an approved indoor/outdoor, 3-wire, grounding type cord. Do

not allow any part of the cord or the receptacle ends to sit in water or in damp locations.

Unplug the pump before servicing. To avoid

Manual background fatal shock, proceed as follows if the pump needs servicing.

A.Disconnect the power to the pump outlet box before unplugging the pump. After the plug is pulled, let the pump cool for 20 minutes before attempting to work on it.

B.Take extreme care when changing fuses. To reduce the chance of fatal electrical shock, DO NOT stand in water or put your finger in the fuse socket.

C.Ground the electrical outlet box.

D.Plug the pump and the controller into a Ground Fault Circuit Interrupter (GFCI) protected grounded outlet only.

For parts or assistance, call Simer Customer Service at 1-800-468-7867