Environmental requirements
Before you install your SMART Board 480iv interactive whiteboard system, review the following
environmental requirements.
Environmental
requirement
Parameter
Operating temperature l5°C to 35°C (41°F to 95°F) from 0 m to 1800 m (0' to 6000')
l5°C to 30°C (41°F to 86°F) from 1800 m to 3000 m (6000' to 9800')
Storage temperature l-20°C to 70°C (-4°F to 158°F) at 5% to 90% relative humidity (non-
condensing)
Humidity l30% to 80% relative humidity, non-condensing
l5% to 85% relative humidity at 0 m to 3000 m (0' to 9800')
Water and fluid
resistance
lIntended for indoor use only. Doesn’t meet any salt-spray or water
ingress requirements.
lDon’t pour or spray liquids directly onto your interactive whiteboard,
the SMART V25 projector or any of its sub-components.
Dust lIntended for use in office and classroom environments. Not for
industrial use where heavy dust and pollutants can cause
malfunctions or impaired operation. Periodic cleaning is required in
areas with heavier dust.
lDesigned for pollution degree 1 (P1) as per EN61558-1, which is
defined as “No pollution or only dry non-conductive pollution”.
Electrostatic discharge
(ESD)
lEN61000-4-2 severity level 4 for direct and indirect ESD
lNo malfunction or damage up to 8kV (both polarities) with a 330
ohm, 150 pF probe (air discharge)
lUnmated connectors meet no malfunction or damage up to 4kV
(both polarities) for direct (contact) discharge
Cables lAll SMART Board 480iv interactive whiteboard system cables
should be shielded to prevent potential accidents and degraded
video and audio quality.
Conducted and radiated
emissions
lEN55022/CISPR 22, Class A