10 | INSTALLING AND SECURING YOUR SMART BOARD V280 INTERACTIVE
WHITEBOARD
Environmental Requirements
Before installing your SMART Board V280 interactive whiteboard, review the following
environmental requirements.
Environmental
Requirement Parameter
Operating temperature 41°F to 95°F (5°C to 35°C)
Storage temperature -40°F to 120°F (-40°C to 50°C)
Humidity 5–80% relative humidity, non-condensing
Water and fluid
resistance
Intended for indoor use
Don’t pour or spray liquids directly on the electronic
components
Dust
Moderate dust
Designed for pollution degree 1 (P1) as per EN61558-1,
which is defined as “No pollution or only dry
non-conductive pollution.” Refer to page45 for detailed
instructions on periodically cleaning your interactive
whiteboard.
Electrostatic discharge
(ESD)
Designed to withstand electrostatic shock
EN61000-4-2 severity level 4 for direct and indirect ESD
No malfunction or damage up to 15kV (both polarities)
with a 330 ohm, 150 pF probe (air discharge)
Unmated connectors meet no malfunction or damage
up to 8kV for direct (contact) discharge
Conducted and
radiated emissions
EN55022/CISPR 22, Class B
Flammability rating Electronics and connectors: UL 94-V0
USB enclosure (hub plastics): UL94-HB
USB 2.0 cable: UL VW-1/CSA FT4
Quality assembly USB cable: IPC/WHMA-A-620 Class 2 workmanship
standards for Requirements & Acceptance for Cable &
Wire Harness
Digital cameras: IPC-A-610 standards for Acceptability
of Electronic Assemblies, to Class 2 specifications
(Dedicated Service Electronic Parts)