SMC CORPORATION
SI unit I/O data (Receiving and sending data of polled command)
Item |
| Output(Poll request) | Input(Poll response) |
Occupied byte | 2 byte | 2 byte | |
|
| (Solenoid valve output) |
|
Sending/ | Address +0 | Output No. 0 to 7 |
|
receiving data | Address +1 | Output No. 8 to 15 |
|
*) Mapping method of sending / receiving data is different by PLC.
For further information, refer to the manual for PLC master (scanner)
|
| Bit of each output data and corresponding solenoid valve no. | ||||||||||
| Offset | MSB |
|
|
|
|
|
|
|
| LSB | |
| 0 | No.7 | No.6 |
| No.5 | No.4 | No.3 | No.2 | No.1 | No.0 | ||
| 1 | No.15 | No.14 |
| No.13 | No.12 | No.11 | No.10 | No.9 | No.8 | ||
|
|
|
|
|
| |||||||
| SI unit |
| Valve series |
|
|
|
|
|
|
| ||
| EX120 |
| VQ1000, VQ2000 |
|
|
|
|
|
| |||
| EX121 |
| VQ1000, VQ2000, SX3000, SX5000 |
|
|
|
| |||||
| EX122 |
| SY3000, SY5000 |
|
|
|
|
|
| |||
| EX124U/D | VQ2000, VQ4000, VQ5000 |
|
|
|
|
|
3. Wiring and Setting
DeviceNet can be connected by T branch, Multi branch, Branch line branch and Multi drop. Total extension length of trunk and Branch line is different for different Baud rate and thickness of communication cable.
Main line
Terminal resistance |
| Terminal resistance |
|
Multi branch
Branch
line
Node |
| Node |
|
|
|
Node
Node
Node
Branch
line
| Branch line |
T branch | branch |
| |
| Node |
Node | Node |
|
Branch
line
Length of cable
Node
Communication | Baud rate | Total length of | Length of | Total length of | ||
distance | trunk | branch line | branch line | |||
| ||||||
| Thick cable | 500 kbps | 100m or less | 6m or less | 39m or less | |
| 250 kbps | 250m or less | 78m or less | |||
|
| 125 kbps | 500m or less |
| 156m or less | |
| Thin cable | Common | 100m or less | ―――――― | ||
Terminal resistance |
| 121 ohm (1/2W) |
|
- 5 -