| 2. Specifications |
|
|
|
|
|
|
|
| SMC CORPORATION | |||||||
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
| Item |
|
|
|
|
| Specifications |
|
|
|
|
|
|
| |||
|
| Model |
|
|
| EX120 | EX121 | EX122 |
| EX124D | EX124U |
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
| Operating ambient temp. |
| 0 to +55(with 8 points of valve ON) |
|
| ||||||||||||
|
|
|
|
|
|
|
|
| 0 to +50℃(with 16 points of valve ON) |
|
| |||||||
|
| Operating ambient humidity |
| 35 to 85%RH(No dew condensation) |
|
| ||||||||||||
|
| Storage ambient temp. |
|
|
|
|
|
|
|
| ||||||||
|
| Vibration proof |
|
|
| 50m/s2 (comply with JIS C 0911) |
|
| ||||||||||
|
| Impact proof |
|
|
| 100m/s2 (comply with JIS C 0912) |
|
| ||||||||||
|
| Noise immunity |
|
|
| Normal mode | ±1500 V Pulse 1µs |
|
| |||||||||
|
|
|
|
|
|
|
|
| Common mode | ±1500 V | Pulse 1µs |
|
| |||||
|
|
|
|
|
|
|
|
| Radiation |
| 1000 V ±Pulse 1µs |
|
| |||||
|
| Withstand voltage |
| AC1000V for 1 min. between FG and external |
|
| ||||||||||||
|
|
|
|
|
|
|
|
| terminal package. |
|
|
|
|
|
| |||
|
| Insulation resistance |
| DC500V, 2MΩ between FG and external terminal |
|
| ||||||||||||
|
|
|
|
|
|
|
|
| package. |
|
|
|
|
|
|
|
|
|
|
| Operating environment |
| No corrosive gas and no dust |
|
| ||||||||||||
|
| Weight |
|
|
| 110g |
| 140g | 130g |
| 240g |
|
| |||||
|
|
|
|
|
|
|
|
| or less |
| or less | or less |
| or less |
|
| ||
|
| Protection class |
|
|
|
|
| IP20 |
|
| IP65 |
|
| |||||
|
|
|
|
|
|
|
|
|
| |||||||||
|
| Item |
|
|
|
|
|
|
| Specifications |
|
|
|
|
| |||
|
| Applicable system |
|
| DeviceNet Release 2.0 |
| ||||||||||||
|
| Power supply voltage for communication |
| DC11V to DC25V |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
| (supplied by communication connector) |
| ||||||
|
| Power supply voltage for solenoid valve |
| DC24V +10% |
| |||||||||||||
|
| Consumption |
| Communication and |
| 90mA or less (DC24V) |
| |||||||||||
|
| current |
| Internal power supply |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| Power supply for |
| 1.5A or less (DC24V) |
| |||||||||
|
|
|
|
|
| Solenoid valve |
|
|
|
|
|
|
|
|
| |||
|
| Solenoid valve |
| Output style |
|
| NPN output (Open collector) |
| ||||||||||
|
| Connection |
| Connected load |
| DC24V, Solenoid valve with |
| |||||||||||
|
| spec. |
|
|
|
|
|
|
| protection circuit of 2.1W or less. |
| |||||||
|
|
|
|
|
|
|
|
|
|
| (made by SMC) |
| ||||||
|
|
|
|
|
| Insulation type |
|
| ||||||||||
|
| Residual voltage |
|
|
|
|
|
| 0.4V DC or less |
|
|
|
|
| ||||
|
| spec. |
| Applicable DeviceNet |
|
| VolumeⅠ- Release 1.2 |
| ||||||||||
|
|
| MAC ID setting range |
|
| 0 to 63 (Set by Dip switch) |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| VolumeⅡ- Release 1.1 |
| ||||||
|
| connection |
|
|
|
|
| |||||||||||
|
|
| Baud Rate (Transmission speed) |
| 500kbps, 250kbps, 125kbps (Set by Dip switch) |
| ||||||||||||
|
|
| Slave (branch station) type |
| Group 2 only server |
| ||||||||||||
|
|
|
|
|
| |||||||||||||
|
|
|
| Connection type |
|
| T branch type, Multi drop type |
| ||||||||||
|
|
|
| Device type |
|
|
|
|
| 16 |
|
|
|
|
|
|
| |
|
| Network |
| Product code |
|
| 288 |
|
|
|
|
|
| |||||
|
|
| Revision |
|
|
|
|
| Referred to EDS file. |
| ||||||||
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
| Vendor ID |
|
|
|
|
| 7 |
|
|
|
|
|
|
| |
|
|
|
| Corresponding message |
|
| Polled command (I/O message ), Explicit message |
|