SMC Networks SMC8624T manual Selecting a Site, Installing The Switch

Models: SMC8624T

1 80
Download 80 pages 51.33 Kb
Page 37
Image 37
CHAPTER 3 INSTALLING THE SWITCH

CHAPTER 3 INSTALLING THE SWITCH

Selecting a Site

TigerSwitch 10/100/1000 units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location.

The site should:

be at the center of all the devices you want to link and near a power outlet.

be able to maintain its temperature within 0 to 50 °C (32 to

122 °F) and its humidity within 5% to 95%, non-condensing

provide adequate space (approximately two inches) on all sides for proper air flow

be accessible for installing, cabling and maintaining the devices

allow the status LEDs to be clearly visible

Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference, such as radios and transmitters.

Make sure that a separate grounded power outlet that provides 100 to 240 VAC, 50 to 60 Hz, is within 2.44 m (8 feet) of each device and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor is recommended.

3-1

Page 37
Image 37
SMC Networks SMC8624T manual Selecting a Site, Installing The Switch