Technica l Data  SMA Technolo gie AG
Page 78 SMC50A_60A-IEN073320 Installation Guide
14.2 Sunny Mini Central SMC 6000ADescription  Short
descr.
Setting
PV Generator Connection Data
Max. input open circuit voltage UPV 0 600 V (based on -10 °C cell
temperature)
Input voltage, MPP range UPV 213 V - 600 V @ UACmin
(246 V - 600 V DC @ 230 V AC)
Max. input current IPV, max 26 A
Max. input power PDC 6300 W 
All-pole isolator on 
the DC input side
DC plug connector
Overvoltage protection thermally monitored varistors
Voltage ripple UPP < 10 % of the input voltage
Personal protection insulation monitoring 
(Riso > 1 MW)
Operating consumption < 7 W
Reverse polarity protection via short-circuit diode