SMA Technol ogie AG Technica l Dat a
Installation Guide SMC50A_60A-IEN073320 Page 79
Grid Connection Data
Nominal output power PACnom 6000 W
Peak output power PAC, max 6000 W
Nominal output current IACnom 26 A
Max. output current IAC, max 26 A
Harmonic distortion of output current
(at KUgrid < 2 %,
PAC > 0.5 PACnom)
KIAC < 4 %
Short-circuit proofing current control
Nominal operational voltage UACnom 230 V
Operating range, grid voltage
(complying with
DIN VDE 0126-1-1)
UAC 198 ... 253 V / 260 Va
Voltage range
(extended operating range)
UAC 180 V - 265 V
Nominal operating frequency fACnom 50 Hz / 60 Hz
Operating range, grid frequency
(complying with
DIN VDE 0126-1-1)
fAC 47.5 Hz - 50.2 Hz
Frequency range
(extended operating range)
fAC 50 Hz: 45.5 Hz - 54.5 Hz
60 Hz: 55.5 Hz - 64.5 Hz
All-pole isolator on grid side automatic disconnection device
(SMA grid guard 2)
Power factor cos phi 1
Overvoltage category III
Test voltage (50 Hz) 2 kV
Test surge voltage 4 kV (serial interface: 6 kV)
Operating consumption in night
mode
0.25 W
Description Short
descr.
Setting