Instructions for the installer

3.2 Burner and nozzle characteristics table

 

 

 

Nominal gas

 

 

 

 

 

 

 

 

Burner

 

consumption

 

 

LPG – 2.75 kPa

 

 

 

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn-down gas

 

 

Injector

 

 

 

 

 

 

 

consumption

 

 

(mm)

 

 

 

 

 

 

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

3.9

 

 

1.3

 

 

0.54

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid

 

6.3

 

 

1.6

 

 

0.68

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

 

10.8

 

2.7

 

 

0.88

 

 

 

 

 

 

 

 

Wok

 

13.5

 

5.8

 

 

1.00

 

 

 

 

 

 

 

 

 

 

 

 

 

Fish pan

 

6.8

 

2.9

 

 

0.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

 

 

 

 

 

 

 

Burner

 

consumption

 

 

 

NG – 1.00 kPa

 

 

 

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn-down gas

 

 

Injector

 

 

 

 

 

 

 

consumption

 

 

(mm)

 

 

 

 

 

 

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary3.9

Semi-rapid7.5

Rapid12

Wok15

 

Fish pan

 

7.8

 

 

 

 

 

1.3

 

0.90

 

 

 

 

1.6

 

1.20

 

 

 

 

2.7

 

1.55

 

 

 

 

5.8

 

1.75

 

 

 

 

2.9

 

1.26

3.3 Arrangement of burners on cooking hob

BURNERS

1

Auxiliary

2

Semi rapid

3

Rapid

4

Wok

5

Fish pan

12

Page 10
Image 10
Smeg A11A-5 manual Burner and nozzle characteristics table, Arrangement of burners on cooking hob