Smeg A11A-6 manual Final Operations, Instructions for the installer, Regulation of minimum for LPG

Models: A11A-6

1 32
Download 32 pages 9.76 Kb
Page 11
Image 11
4. FINAL OPERATIONS

Instructions for the installer

4. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

After adjustment to a different kind of gas from the one for which the cooker has been tested, replace the plate inside the storage compartment with one corresponding to the new kind of gas. This plate can be obtained from your nearest Authorised Assistance Centre.

4.1Adjustment of minimum for natural gas

Light the burner and take it to the minimum. Remove the gas tap knob and turn the

adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

4.2 Regulation of minimum for LPG

For regulating the minimum with LPG, the screw at the side of the tap rod must be turned clockwise all the way.

The bypass diameters for each individual burner are shown in paragraph “3.2 Burner and nozzle characteristics table”. Once the regulation has been completed, replace the seal on the by-passes using paint or similar materials.

4.3 Positioning and levelling of the appliance

Having carried out the electricity and gas hook-up, level the appliance using the four adjustable legs.

13

Page 11
Image 11
Smeg A11A-6 manual Final Operations, Instructions for the installer, Adjustment of minimum for natural gas