Smeg A21X-6 Instructions for the installer, Installation Of The Appliance, Electrical connection

Models: A21X-6

1 32
Download 32 pages 10.29 Kb
Page 4
Image 4
Instructions for the installer

Instructions for the installer

2. INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by authorised persons. Clearance around the cooker must comply with the requirements of AS5601.

2.1 Electrical connection

Make sure that the power line voltage matches the specifications indicated on the rating plate located inside the storage compartment.

This rating plate must never be removed.

The plug at the end of the power cable and the wall socket must be the same type (conforming to regulations in force). Check that the power line is adequately grounded. Do not use reducers, adapters or shunts.

On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.

Use an H05RR-F-type three-core cable (3 x 2.5 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.

Overall dimensions: location of gas and electrical connection points (all measures in mm).

A 110

B 760

C 150

D 170

6

Page 4
Image 4
Smeg A21X-6 manual Instructions for the installer, Installation Of The Appliance, Electrical connection