MicroMMAC-24TTOKEN RING HUB WITH LANVIEW®

SUPPORTING 100 OHM STP CABLE

Figure 3-1. Attaching the Strain Relief Bracket

3.3 INSTALLING THE MicroMMAC-T

The MicroMMAC-T can be rack-mounted, wall-mounted, or placed on any horizontal surface. Refer to the following subsections for the appropriate installation instructions. When installing the MicroMMAC-T into something other than a 19-inch rack, installation requires the following:

An unrestricted free surface area at least 21 inches wide, 18 inches deep, and 6 inches high.

A single phase 85 to 264 Vac, 15A, grounded power receptacle located within 7 feet of the site.

If a shelving unit is used, it must be able to support 30 pounds of static weight.

The temperature in selected location must be between 5° and 50°C, and change less than 10°C per hour.

NOTE: Be sure that the selected location is within reach of the network cabling.

3.3.1 Rack-Mounting the MicroMMAC-T

Refer to Figure 3-2 and perform the following steps to install the MicroMMAC-T in a 19-inch rack:

1.Remove the four cover screws located along the front edges of each side of the MicroMMAC-T.