SAVE/EXECUTE

LOCAL MANAGEMENT

it sends a trap to the NMS informing it that the station could not be removed. The station must then be physically removed from the ring.

SAVE/EXECUTE

Use this field to save changes made to ring security in the MicroMMAC-T’s NVRAM. You must use the SAVE/EXECUTE command for your changes to take effect.

NEXT_SCREEN

Use this command to scroll to the next screen of the allowed list database.

PREVIOUS_SCREEN

Use this command to scroll back to the previous screen of the allowed list database.

RETURN

Use this command to exit the RING SECURITY screen and return to the SETUP MENU screen.

Changing the Security Mode

1.Highlight the Security Mode field.

2.Toggle through options (Disabled, Alarm Only, Remove/Alarm) and select the desired option.

3.Highlight the SAVE/EXECUTE command and then press the Return key.

The MicroMMAC-T enables the selected mode of ring security. The following message appears at the top of the screen: “SECURITY MODE CHANGED.”

Building the Allowed List Automatically

1.Set the Security Mode to Disabled (as described above) and then set the Security Mode to Alarm Only.

Ring Security automatically builds an allowed list only after the Alarm Only mode has been invoked from the Disabled mode.