Smeg A2EA Final Operations, Adjustment of minimum for natural gas, Regulation of minimum for LPG

Models: A2EA

1 32
Download 32 pages 9.43 Kb
Page 9
Image 9
4. FINAL OPERATIONS

Instructions for the installer

4. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

After adjustment to a different kind of gas from the one for which the cooker has been tested, replace the plate inside the storage compartment with one corresponding to the new kind of gas. This plate can be obtained from your nearest Authorised Assistance Centre.

4.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum 4.1 Adjustment of minimum for natural gas. Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

4.2 Regulation of minimum for LPG

To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model).

The diameters of the by-passes for each burner are given in table “3.2 Burner and nozzle characteristics table”.

4.3 Positioning and levelling of the appliance

Having carried out the electricity and gas hook-up, level the appliance using the four adjustable legs.

11

Page 9
Image 9
Smeg A2EA manual Final Operations, Adjustment of minimum for natural gas, Regulation of minimum for LPG