Instructions for the Installer

3.3 Burner and Nozzle Data Tables (90 cm Models)

 

 

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

 

heat

 

 

 

 

BOTTLED GAS - G30/G31 30/37 mbar

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

 

By-pass

 

Reduced

 

 

Flow-rate

 

Flow-rate

 

 

 

 

diameter

 

 

mm

 

heat capacity

 

 

g/h G30

 

g/h G31

 

 

 

 

1/100 mm

 

 

1/100

 

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

1

 

50

 

 

30

 

350

 

 

73

 

71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid

 

1.75

 

65

 

 

33

 

450

 

 

127

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

 

3

 

85

 

 

45

 

800

 

 

218

 

214

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple Flame

 

3.2

 

91

 

 

65

 

1500

 

 

233

 

229

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fish

 

1.9

 

68

 

 

45

 

800

 

 

138

 

136

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

 

3.2

 

87

 

 

48

 

850

 

 

233

 

229

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maxi oven

 

5.2

 

110

 

 

59

 

1200

 

 

378

 

371

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grill

 

2.9

 

87

 

 

//

 

//

 

 

218

 

214

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maxi grill

 

4.0

 

100

 

 

//

 

//

 

 

291

 

286

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

 

heat

 

 

 

 

TOWN GAS – G110 8 mbar

 

 

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

 

 

Reduced heat capacity

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

1

 

 

145

 

 

 

 

 

 

350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid

 

1.75

 

 

190

 

 

 

 

 

 

450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

 

3

 

 

260

 

 

 

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Triple Flame

 

3.5

 

 

290

 

 

 

 

 

 

1500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fish

 

1.9

 

 

190

 

 

 

 

 

 

800

 

 

G110 gas cannot be used in models with gas oven.

The data for town gas refer to category III 1a2H3+ appliances.

 

 

Rated

Burner

 

heat

 

 

capacity

 

 

(kW)

 

 

 

Auxiliary

 

1

 

 

 

Semi-rapid

 

1.75

 

 

Rapid

 

3

 

 

Triple Flame (4)

 

3.5

 

 

Triple Flame (8)

 

3.5

 

 

Fish

 

1.9

 

 

Oven

 

3.2

 

 

Maxi oven

 

5.2

 

 

Grill

 

2.9

 

 

Maxi grill

 

4.0

NATURAL GAS - G20 20 mbar

Nozzle diameter

 

Reduced heat capacity

1/100 mm

 

(W)

 

 

 

72

 

350

 

 

97

 

450

 

 

115

 

800

 

 

133

 

1500

 

 

 

140

 

1500

 

 

 

94

 

800

 

 

 

130

 

850

 

 

164

 

1200

 

 

130

 

//

 

 

150

 

//