16.4.1 Connection of natural and town gas

Instructions for the installer

CONNECTION USING RUBBER HOSES COMPLYING WITH THE CURRENT REGULATIONS IS ONLY PERMITTED IF THE HOSE CAN BE INSPECTED ALONG ITS ENTIRE LENGTH.

16.4.1 Connection of natural and town gas

Make the connection to the gas mains using a rubber hose whose specifications comply with the current regulations (verify that the reference standard is stamped on the hose).

Screw the hose connector A to the gas connector B of the appliance, placing with the seal Cbetween them. Push the rubber hose D onto the hose connector A and secure it with the clamp E that is compliant with the current standard.

16.4.2Connection to LPG

Both the pressure regulator and the connection to the cylinder must be standards-compliant. make sure that the feed pressure complies with the values indicated in the table at point “17.2 Burner and nozzle characteristics table”.

Screw the small hose connector F onto the large hose connector A; connect the block this makes to the gas connector B (or use the hose connector G which must be connected directly to the gas connector B) and place the seal Cbetween them. Push the end of the rubber hose H onto the hose connector A+F (or G) and at the outlet connector of the pressure reducer onto the cylinder. Fix the end of the hose H to the hose connector A+F (or G) with the standards-compliant clamp I

The hose connector A-F-Gillustrated are not supplied with the appliance. Only use standards-compliant hose connectors.

16.4.3Connection with flexible steel hose (for all types of gas)

This type of connection can be made on both built-in and free-standing appliances. Only use standards-compliant steel hoses whose length is not greater than 2 metres.

Screw the end of the flexible hose L to the ½” OD threaded gas connector (ISO 228-1) B placing the seal C between them.

At the end of the installation, check for any leaks with a soapy solution, never with a flame.