Instructions for the installer
17.ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any operations requiring access to powered parts, switch off the power supply to the appliance.
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.
17.1 Replacement of nozzles on the hob
This operation does not require the primary air to be adjusted.
1Extract the grids and remove all the caps and
2Unscrew the burner nozzles with a 7 mm socket wrench;
3Replace the nozzles according to the type of gas to be used and the description in paragraph "17.2 Burner and nozzle characteristics table";
4Replace the burners in the correct position.
62