![TECHNICAL CHARACTERISTICS](/images/new-backgrounds/71971/719717x1.webp)
2Technical characteristics
TECHNICAL CHARACTERISTICS
|
| CWC500R |
Input voltage power | V | 400V 3N ~ |
- transformable to version | V | |
Frequency | Hz | 50 |
Max. absorbed power at 400V 3N ~ | kW | 11,1 |
Boiler resistance power at 400V 3N ~ | kW | 10,0 |
Tank resistance power | kW | 3,0 |
Water supply pressure | kPa (bar) | |
Water supply temperature | °C | 50°C – 60°C |
Water supply hardness | °dF | |
Rinse cycle water consumption | l | 3,9 |
Boiler capacity | l | 9 |
Tank capacity | l | 35 |
Standard cycle duration with water supply at 50°C | s | 90/120/180/c |
Noise level | dB(A) | 67 |
Protection rating | IPX | 4 |
Net weight | kg | 127 |
Power cable type | ◄HAR► |
Electrical scheme - legend
PV | Tank Pressostat |
ISP | Door Safety Switch |
STV | Tank Temperature Sensor |
STB | Boiler Temperature Sensor |
TRB | Boiler Resistance Remote Control Switch (Coil) |
TRV | Tank Resistance Remote Control Switch (Coil) |
E | Rinse Electrovalve |
DB | |
P | Wash Pump |
DD | Detergent Metering Unit |
PBT | Break Tank Pressostat |
PR | Rinse pump |
TP | Wash Pump Remote Control Switch (Coil) |
TPL | Wash Pump Thermal |
TS | Safety Thermostat |
F | Antistatic filters |
Electrical Scheme – voltage regulation
400/3 Volt |
|
|
|
| 230/3 Volt |
|
|
|
|
|
| TRB | TRB |
R | S | T | R | S | T |
|
400/3 Volt | 230/3 Volt |
|
|
Wash Pump | Boiler Resistance |
3