| Instructions for the Installer |
| |||||
|
|
|
| |||||
| 10.2 Burner and Nozzle Data Tables |
|
| |||||
|
|
|
|
|
|
|
|
|
|
| RATED |
|
|
|
|
|
|
Burner | HEAT |
| LPG – G30/G31 28/37 mbar |
| ||||
CAPACITY |
|
| ||||||
|
|
|
|
|
|
|
| |
|
| (KW) |
|
|
|
|
|
|
|
|
| Nozzle | Reduced |
|
| ||
|
|
| heat | Net | Net | |||
|
|
| diameter | mm | ||||
|
|
| capacity | g/h G30 | g/h G31 | |||
|
|
| 1/100 mm | 1/100 | ||||
|
|
| (W) |
|
| |||
|
|
|
|
|
|
|
| |
Auxiliary (!) | 1.05 | 50 | 30 * | 28 ** | 350 | 76 | 75 | |
1.75 | 65 | 33 * | 32 ** | 450 | 127 | 125 | ||
Rapid (3) | 2.3 | 75 | 45 * | 42 ** | 800 | 167 | 164 | |
Fish pan (4) | 1.9 | 68 | 45 * | 42 ** | 900 | 138 | 136 | |
|
|
|
|
|
|
|
|
|
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in point "11.1 Adjusting the minimum setting for natural gas".
|
| RATED |
|
| |
Burner | HEAT | NATURAL GAS – G20 20 mbar | |||
CAPACITY | |||||
|
|
|
| ||
|
| (KW) |
|
| |
|
|
| Nozzle diameter | Reduced heat capacity | |
|
|
| 1/100 mm | (W) | |
Auxiliary (!) | 1.05 | 72 | 350 | ||
1.75 | 97 | 450 | |||
Rapid (3) | 2.5 | 108 | 800 | ||
Fish pan (4) | 1.9 | 94 | 900 | ||
|
| ||||
| To identify the burners on your hob, refer to the drawings in point "4. | ||||
| GETTING TO KNOW YOUR APPLIANCE". |
| |||
|
|
|
|
| |
|
|
|
|
|
37