Smeg GD100XG manual Electrical connection, Instructions for the Installer

Models: GD100XG

1 18
Download 18 pages 63.8 Kb
Page 13
Image 13
8.3Electrical connection

Instructions for the Installer

8.3Electrical connection

Check that the power supply voltage and size are as specified on the nameplate below the appliance carter.

The nameplate must never be removed.

The appliance must be connected to earth in compliance with electrical system safety regulations.

If a permanent connection is used, the appliance's power supply line must be fitted with an omnipolar breaking device with contact gap of at least

3mm, located in an easily accessible position close to the appliance itself.

If a socket and plug connection is used, check that they are of the same type. Do not use reducers, adapters or junctions since they may cause overheating or burns.

Operation at 220-240 V~: use a type H05V2V2-Fthree-wire cable (cable of 3

x 1.5 mm2 for electric hobs and a cable of 3 x 0.75 mm2 for gas hobs)

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

The manufacturer declines all responsibility for injury or damage caused by failure to comply with the above regulations or deriving from tampering with even just one part of the appliance.

33

Page 13
Image 13
Smeg GD100XG manual Electrical connection, x 1.5 mm2 for electric hobs and a cable of 3 x 0.75 mm2 for gas hobs