Smeg GKC64-3, GKC95-3 manual Regulation for G25/25 mbar, Instructions for the installer

Models: GKC64-3 GKC95-3

1 20
Download 20 pages 29.96 Kb
Page 11
Image 11
5.4Regulation for G25/25 mbar
Methaangas – G25 25 mbar

Instructions for the installer

5.4Regulation for G25/25 mbar

The hob has been inspected for G25 (2L3B/P) at a pressure of 25 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.3 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph “5.5 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

Rated

Burnerheating capacity

 

 

 

 

Nozzle diameter

Reduced flowrate

 

 

 

 

1/100 mm

(W

 

 

 

 

 

400

Auxiliary

1.05

76

 

 

 

 

 

450

Semirapid

1.7

 

98

 

 

 

 

 

750

Rapid

2.55

 

120

 

 

 

 

 

750

Rapid large

3.3

 

132

 

 

 

 

 

950

Fish pan

2.9

 

126

 

 

 

 

 

1400

Ultra rapid

4.1

 

150

33

Page 11
Image 11
Smeg GKC64-3, GKC95-3 manual Regulation for G25/25 mbar, Instructions for the installer