Instructions for the installer

5.5Regulation of primary air

Referred to distance “A” in mm.

60 cm hobs with separable control panel.

Burner

G25

G30/G31

25 mbar

Auxiliary (1)

 

2.5

 

 

 

Semirapid r (2)

 

0.5

 

 

 

Semirapid l (3)

 

0.5

 

 

 

Rapid large (4)

 

0

 

 

 

Ultrarapid (5)

 

2.0

90 cm hobs with separable control panel.

28/37 mbar

2.5

2.0

1.5

2.5

4.0

Burner

G25

G30/G31

25 mbar

Auxiliary (1)

 

2.0

 

 

 

Semirapid (2)

0.5

 

 

 

Rapid (3)

-0.5

 

 

 

Fish burner (4)

-1.0

 

 

 

Ultrarapid (5)

1.5

60 cm hob with built-in control panel.

28/37 mbar

2.5

2.0

1.5

8.0

5.5

Burner

G25

G30/G31

25 mbar

Auxiliary (1)

 

2.5

 

 

 

Semirapid r (2)

 

0.5

 

 

 

Semirapid l (3)

 

0.5

 

 

Rapid medio (4)

 

0.0

 

 

Ultrarapid (5)

 

1.0

28/37 mbar

2.5

2.5

2.0

2.5

3.0

To identify the burners on your hob, refer to the drawings in point “6.3/6.4 Arrangement of burners on hob “