Smeg GKC95-3, GKC64-3 manual Instructions for the installer, Burner

Models: GKC64-3 GKC95-3

1 20
Download 20 pages 29.96 Kb
Page 10
Image 10
Burner

Instructions for the installer

following the instructions given in the tables for bottled gas G30/G31 – 28/37 mbar. The nozzle must not be tightened to a torque of over 3 Nm. Regulate the air flow by moving the Venturi pipe “C”, until the gap “A” is as shown in the table in point “5.5 Regulation of primary air” and fix it with the screw “D”. After making the adjustments, restore the seals with sealing wax or an equivalent material.

Burner

Rated

heatingLPG – G30/G31 28/37 mbar capacity

Nozzle

 

 

 

 

 

 

 

 

 

 

 

By-pass

 

By-pass

 

Reduced

 

 

 

 

Diameter

 

 

 

 

Flowrate

 

Flowrate

 

1/100 mm

 

1/100 mm

 

flowrate

 

 

1/100

 

[V(1)]

 

[NV(1)]

 

(W)

 

g/h G30

 

g/h G31

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.05

48

 

30

 

30

 

400

 

76

 

75

 

1.7

 

 

 

 

 

 

Semi-rapid

62

 

32

 

32

 

450

 

124

 

121

 

2.55

 

 

 

 

 

 

Rapid

76

 

42

 

42

 

750

 

185

 

182

 

3.1

 

 

 

 

 

 

Rapid large

85

 

42

 

42

 

750

 

225

 

222

 

2.9

 

 

 

 

 

 

Fish pan

82

 

48

 

50

 

950

 

211

 

207

 

4.0

 

 

 

 

 

 

Ultra rapid

95

 

63

 

65

 

1600

 

291

 

286

(1)V = Valved; NV = Nonvalved