9. ADAPTATION TO DIFFERENT TYPES OF GAS

Instructions for the installer

9. ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance from the electricity supply.

The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

9.1Replacement of nozzles on the hob

1Extract the pan stands and remove all the caps and flame-spreader crowns;

2Unscrew the burner nozzles with a 7 mm socket wrench;

3Replace the burner nozzles according to the type of gas to be used (see point “9.2 Burner and nozzle characteristics table“).

4Replace the burners in the correct position.

The nozzles for using town gas (G110 – 8 mbar) are available from authorised service centres.