Instructions for the installer

7.INSTALLING THE APPLIANCE

7.1Positioning

This is a class 1 (B2) and 3 (A, B1)appliance.

The following operation requires building and/or carpentry work, therefore it must be carried out by a skilled technician.

Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C).

7.2Heights for type A installation (empty base)

A

DISTANCES

A

B

C

L

H

MINIMUM

866 mm

630 mm

50 mm

904 mm

750 mm

MAXIMUM

866 mm

650 mm

-

-

-

 

 

 

 

 

 

The supporting strips must be of the appropriate size and secured to the base in order to support the weight of the product and its use.

30

Page 9
Image 9
Smeg HB96CSS-3, HB96GXBE3 manual Instructions for the installer, Installing the Appliance, Positioning