Smeg KSM36XU, KSM24XU manual Chimney assembly, Electrical Connection

Models: KSM24XU KSM36XU

1 13
Download 13 pages 63.98 Kb
Page 10
Image 10

ELECTRICAL CONNECTION

Remove the cover from the Field Wiring Compartment with a phillips screwdriver.

Feed the Power Supply Cable through the electrical knockout. Connect the Power Supply Cable to the range- hood cable. At- tach the Power Supply Cable grounding lead to the green screw provided. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connec- tor. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector.

Replace the cover.

Green Ground screw

Ground wire

Power supply cable

Chimney assembly

Upper exhaust chimney

• Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated.

• Secure the sides to the brackets using the 4 screws 12c sup-

2.1

 

plied.

2

 

 

8b

Lower exhaust chimney

2.2

 

Slightly widen the two sides of the flue and hook them be-

 

 

tween the upper flue and the wall, making sure that they are

 

 

well seated.

 

Fix the lower part laterally to the hood body using the 2 screws

 

 

12c supplied.

 

On the recirculation version, fit the directional grids 8a – 8b in their housings making sure that the directional symbols are to- wards the top and front of the hood. Also make sure that they are correctly inserted in the connection extension pieces 14.1.

7.2.1

12c

8a

12c