Smeg PTS605NU3, PTS605U3, PTS605BU3 important safety instructions Conversion Kit

Models: PTS605NU3 PTS605BU3 PTS605U3

1 6
Download 6 pages 28.62 Kb
Page 2
Image 2
Conversion Kit

Conversion Kit

1)

Check that the main gas supply line to the cooktop is shut off and that the power supply cord is disconnected.

2)

Remove access cap “A” by using a screwdriver or a quarter, turning the access cap counter-clockwise. The gas pressure regulator has two settings which are indicated on two sides of the cap. Turn the cap and reinstall it in the regulator with "LP" visible from the outside of the regulator.

The regulator must be checked at a minimum water column of 1 inch (2.5 cm) above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:

-NATURAL GAS: Set pressure at 6” W.C. Supply pressure of 3 1/2” -

10 1/2” W.C. maximum;

- LP GAS: Set pressure at 10” W.C. Supply pressure of 8” - 13”

W.C. maximum.

The cooktop must be isolated from the gas supply piping system by closing the respective manual shut- off valve during any pressure testing of the gas supply piping system at test pressures equal to or greater than 1/2 psig (3.5 kPa).