Smeg PTS605NU3, PTS605U3, PTS605BU3 Air Shutter, Conversion Kit, Fire Hazard

Models: PTS605NU3 PTS605BU3 PTS605U3

1 6
Download 6 pages 28.62 Kb
Page 5
Image 5
Air Shutter

Conversion Kit

5)

Remove the screw A and push the support B fully down. Remove the nozzle C with a wrench and insert the suitable nozzle following the instructions in the tables referring to the type of gas to be used. The nozzle must not be tightened with a torque of more than 3 Nm. Return the support B to its original position, so that the nozzle C is perfectly covered.

Regulate the air flow by moving the Venturi pipe D until the distance “X” stated in point "5.5 Adjusting the primary air flow” is obtained and secure it with screw A. When theadjustments are complete, restore the seals with wax or a similar material.

6)

Referring to distance “X” in mm.

PTS605U – Natural gas

 

 

Air Shutter

 

 

Left Central

2/ ” - 7.0 mm

 

 

8

Central Front

2/ ” - 7.0 mm

 

 

8

Central Rear

2/ ” - 7.0 mm

 

 

8

Right Central

3/ ” - 4.0 mm

 

 

16

 

PTS727U – Natural gas

 

 

Air Shutter

 

 

 

Left

Inner

3/8” - 10.0 mm

Central

Outer

3/8” - 10.0 mm

Central Front

2/ ” - 7.0 mm

 

 

8

Central Rear

3/ ” - 7.0 mm

 

 

8

Right Front

2/ ” - 7.0 mm

 

 

8

Right Rear

3/ ” - 4.0 mm

 

 

16

PTS605U – LP

 

 

Air Shutter

 

1/2” - 12.0 mm

Left Central

Central Front

2/ ” - 7.0 mm

 

 

8

Central Rear

2/ ” - 7.0 mm

 

 

8

Right Central

3/8” - 10.0 mm

 

 

 

PTS727U– LP

 

 

Air Shutter

 

 

2/ ” - 7.0 mm

Left

Inner

 

8

Central

Outer

1/2” - 12.0 mm

Central Front

2/ ” - 7.0 mm

 

 

8

Central Rear

2/ ” - 7.0 mm

 

 

8

Right Front

2/ ” - 7.0 mm

 

 

8

Right Rear

3/8” - 10.0 mm

 

After carrying out the above adjustments, remount in reverse order to the instructions given in point “3”.

7)

Caution: refit all flame caps in the same points from which they were removed. In fact, the flame cap

 

positions cannot be changed. After refitting them, ensure that they are perfectly positioned and that there

 

is no clearance between the cooktop and the flame caps.

 

FIRE HAZARD

WARNING

- Use a soapy solution to check for proper tightness.

- Never test for gas leaks with a match or other flames.

-Failure to follow this instruction can result in death or fire.

7

Page 5
Image 5
Smeg PTS605NU3, PTS605U3, PTS605BU3 important safety instructions Air Shutter, Conversion Kit, Fire Hazard