4)

To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables below.

PTS605U - Natural gas

 

Qt

Injector

Qr

 

BTU

Ø mm

BTU

 

 

 

 

Left Central

14000

1.60

4400

Central

3400

0.80

1500

Front

 

 

 

 

 

 

 

Central

6000

1.05

1800

Rear

 

 

 

 

 

 

 

Right

9000

1.26

3400

Central

 

 

 

 

 

 

 

PTS605U - LP

 

Qt

Injector

Qr

by-pass

 

BTU

Ø mm

BTU

mm

 

 

 

 

 

Left Central

14000

1.10

4400

0.65

Central

3400

0.54

1500

0.33

Front

 

 

 

 

 

 

 

 

 

Central

6000

0.73

1800

0.37

Rear

 

 

 

 

 

 

 

 

 

Right

9000

0.89

3400

0.50

Central

 

 

 

 

 

 

 

 

 

 

PTS727U - Natural gas

 

 

 

 

PTS727U - LP

 

 

 

Qt

Injector

Qr

 

 

Qt

Injector

Qr

by-pass

 

BTU

Ø mm

BTU

 

 

BTU

Ø mm

BTU

mm

 

 

 

 

 

 

 

 

 

 

Left Central

3000

0.73

1500

 

Left Central

3000

0.50

1500

0.33

Inner

 

Inner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left Central

13000

1.55

4400

 

Left Central

13000

1.05

4400

0.65

Outer

 

Outer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central

3400

0.80

1500

 

Central

3400

0.54

1500

0.33

Front

 

Front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central

6000

1.05

1800

 

Central

6000

0.73

1800

0.37

Rear

 

Rear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Right Front

3400

0.80

1500

 

Right Front

3400

0.54

1500

0.33

Right Rear

9000

1.26

3400

 

Right Rear

9000

0.89

3400

0.50

 

 

 

 

 

 

 

 

 

 

NOTE: Save the nozzles removed from the appliance for future use.