Smeg S340G manual Burner and Nozzle Data Tables, Instructions for the Installer

Models: S340G

1 14
Download 14 pages 45.16 Kb
Page 9
Image 9
5.2 Burner and Nozzle Data Tables

Instructions for the Installer

5.1.4 Adjusting the oven burner primary air flow

• Undo the adjuster screw “A” of the air regulator sleeve;

Turn the regulator sleeve “B” into the position for the type of gas to be used, consulting the table below;

• Tighten the adjuster screw and restore the seals;

• When the operation is complete, reassemble the burner correctly.

 

NATURAL GAS (N)

G30/G31 (LPG)

X =

5 mm

15 mm

 

 

 

When the operation is complete, replace the nameplate on the back of the oven with the one provided for the new type of gas.

5.2 Burner and Nozzle Data Tables

 

Rated heat

 

 

 

 

 

 

Burner

capacity

 

BOTTLED GAS - G30/G31 28/37 mbar

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

By-pass

Reduced

Flow-rate

Flow-rate

 

 

 

diameter

1/100

heat capacity

g/h G30

g/h G31

 

 

 

1/100 mm

mm

(W)

 

 

 

 

 

 

 

 

 

 

 

Oven

2.6

77

41

700

189

186

 

 

 

 

 

 

 

 

 

 

Rated heat

 

 

 

 

 

 

Burner

capacity

 

NATURAL GAS – G20 20 mbar

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

Reduced heat capacity

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

 

Oven

2.6

 

118

 

700

 

 

 

 

 

 

 

 

 

 

25

Page 9
Image 9