Instruction for the installer
4 FINAL OPERATIONS
After replacing the nozzles, reposition the
Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles.
4.1Regulation of the hob burner minimum level for natural gas
Light the burner and turn it to the minimum position . Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.
Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to activate the safety device.
4.2Regulation of the hob burner minimum level for LPG
For regulating the minimum with LPG, the screw at the side of the tap rod must be turned clockwise all the way.
The bypass diameters for each individual burner are shown in paragraph “3.2/3.3 Burner and nozzle characteristics table”. Once the regulation has been completed, replace the seal on the
4.3Regulation of the oven burner minimum level
The oven thermostat is equipped with a
When the gas type is changed, the
1.Turn on the oven burner to maximum for 10/15 minutes with the door closed and without the floor. Turn the knob to the minimum temperature, remove the knob and regulate using a flat screwdriver.
2.For LPG turn the
3.For natural gas, regulate the
4.4Positioning and levelling of the appliance
Having carried out the electricity and gas
14