Instruction for the installer
2.3Connecting to natural and LPG gas
(Please see connection diagram)
Make the connection to the appliance using flexible bayonet style hose in accordance to B.S. 669. The hose connection at the rear of the appliance has a ½” BSP internal thread. Please use seal C between the flexible connection L and the appliance supply tube B. When making the connection, make sure that no stress of any kind is applied to the cooker and that the hose does not touch any sharp edges.
If connecting to LPG the bayonet hose must have red bands on it.
2.3.1Connection to the gas bottle inside the compartment in the cooker (on some models only)
Open the side door and put in a gas bottle (max. 15 kg). Fit one end of the pipe to the pipe holder and fix it to one of the clamps supplied. Insert the pipe into the bottle compartment through the hole in the back of the cooker as shown in the diagram here. Fit the free end of the pipe to the pressure regulator on the gas bottle: fix it with the second clamp. Check for any leaks using a soapy solution, never with a live flame.
To connect the cooker to a gas bottle, use a piece of regulation rubber pipe 1.4 m (± 0.05 m) long
2.3.2Bottled gas connection (Only on some models)
Use a pressure regulator complaint with the relevant standards and make the connection to the gas cylinder in accordance with the relevant regulations.
Make sure that the gas supply pressure is as stated in the table in point "3.2/3.3 Burner and Nozzle Data Tables".
Screw the small hose connector F onto the large hose connector A and connect the resulting unit to the gas union B (or use the hose connector G for connection straight to the gas union B) and fit the seal C. Fit the ends of the rubber hose H onto the hose connector A+F (or G) and to the outlet union of the pressure reducer on the gas cylinder. Fix the end of the hose H to the hose connector A+F (or G) using the regulation hose clamp I .
The hose connector G shown is not supplied with the appliance. Use only hose connectors compliant with the relevant regulations.
8