Instructions for the Installer

13.INSTALLING THE APPLIANCE

13.1Electrical connection

The nameplate with the technical data, serial number and mark is in a visible position on the oven door frame.

The nameplate must never be removed.

The appliance must be connected to earth in compliance with electrical system safety regulations.

If a permanent connection is used, the appliance's power supply line must be fitted with an omnipolar breaking device with contact gap of at least 3 mm, located in an easily accessible position close to the appliance itself.

If a socket and plug connection is used, check that they are of the same type. Do not use reducers, adapters or junctions since they may cause overheating or burns.

Operation at 220-240 V~: use a H05RR-Fthree-wire cable (cable of 3 x 1.5 mm2).

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.