Smeg SE365MF-5 manual Operation at 220-240 V~ use a H05RR-F / H05RN-F three-wire cable

Models: SE365MF-5

1 28
Download 28 pages 40.05 Kb
Page 26
Image 26
13.1.1 Ovens with hob controls

Instructions for the Installer

13.1.1 Ovens with hob controls

On ovens with hob controls the power supply lead is not supplied. Use a H05RR-F or H05RN-F rubber cable and when positioning it ensure that it does not touch the metal parts of the appliance's external casing.

To access the terminal board, remove the appliance's back cover by unscrewing the relative screws. If necessary, change the positions of the jumpers on the terminal board as shown, then connect the wires, making sure that the earth wire is at least 20 mm longer. Fix the power supply lead to the appliance using the cable clamp provided.

Operation at 220-240 V~: use a H05RR-F /H05RN-Fthree-wire cable

(cable of 3 x 4 mm2).

Operation at 380-415V2N~: use a H05RR-F /H05RN-Ffour-wire cable

(cable of 4 x 2.5 mm2).

Operation at 380-415V3N~: use a H05RR-F /H05RN-Ffive-wire cable

(cable of 5 x 1.5 mm2).

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

56

Page 26
Image 26
Smeg SE365MF-5 Operation at 220-240 V~ use a H05RR-F / H05RN-F three-wire cable, cable of 3 x 4 mm2, cable of 4 x 2.5 mm2