ARCNET 5 Port HUB Controller

Datasheet

CONNECTING THE TMC2005 WITH INTERNAL PLL

When using the TMC2005 at data rate 2.5Mbps or lower, it is not necessary to use internal PLL. Leave the loop filter pins (RO, LP) open and connect AGS to the Ground. The pins for the analog power supply (AVSS, AVDD) may connect to digital power supply. When using the TMC2005 at data rate 5Mbps or higher, the internal PLL has to be used as a clock multiplier. PCB layout must follow the guidelines at Figure 10, refer to Notes 1 through 5.

FIGURE 10 - PLL PATTERN LAYOUT

Note 1: Prohibit the patterns for LP and RO from occupying the area of digital power supply. Use the area of analog power supply between VAA and AVSS.

Note 2: Encircle the pattern between LP, RO and AGS with wide pattern of analog ground.

Note 3: Connect the analog power supply “VAA” with 0.1 uF condenser (a) with in 1/8 inch (~ 3.2mm) from VAA pin.

Note 4: In order to filter the jitter of low frequency, connect a 10 uF condenser (b) in parallel with the condenser (a).

Note 5: Place 0.1 uF bypass condenser (c) within ¼ inch (~ 6.4mm) from VDD3 and VSS3. Connect the ground side of a condenser (c) at the place (*) where AVSS returns to GND plane.

SMSC TMC2005-JT

Page 21

Revision 1.1 (07-24-07)

DATASHEET