ARCNET 5 Port HUB Controller

Datasheet

 

 

 

INPUT/

 

 

 

 

FEATURE

NAME

OUTPUT

 

 

DESCRIPTION

 

 

nPLLTST

INPUT

Test pin for PLL.

 

 

 

 

 

Must always connect to VDD.

 

 

AVDD

 

 

Analog power supply

 

 

 

 

 

Using PLL: Analog power supply. There are some

 

 

 

 

 

limits on PCB pattern.

 

 

 

 

 

Using no PLL: Power supply (+5V) same as VDD1~6.

 

 

AVSS

 

 

Analog ground

 

 

 

 

 

 

Using PLL: Analog ground. There are some limits on

 

 

 

 

 

PCB pattern.

 

 

 

 

 

 

Using no PLL: Use a ground same as VSS1~8.

Other Signals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT/

 

 

 

FEATURES

NAME

 

OUTPUT

 

DESCRIPTION

 

CRYSTAL

XTLI

 

INPUT

 

Connect a 20MHz crystal.

 

INTERFACE

 

 

 

 

When supplying an external clock,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

input the clock to this pin.

 

CRYSTAL

XTLO

 

OUTPUT

 

Connect a 20MHz crystal.

 

INTERFACE

 

 

 

 

When supplying an external clock, it

 

 

 

 

 

 

 

must be open.

 

SYSTEM RESET

nRST

 

INPUT

 

Reset for initializing TMC2005. (active

 

INTERFACE

 

 

 

 

Low)

 

TEST PIN

CKO

 

OUTPUT

 

Output internal clock of TMC2005.

 

TEST PIN

nCKOEN

 

INPUT

 

Output control of CKO.

 

 

 

 

 

 

 

0: Output internal clock on CKO.

 

 

 

 

 

 

 

1: Always output Low level on CKO.

 

 

 

 

 

 

 

Set “1” Normally.

 

TEST PIN

RXFLT

 

INPUT

 

It must be open

 

TEST PIN

NC [1:2]

 

 

 

It must be open

 

POWER SUPPLY

VDD [1:6]

 

 

 

Power supply (+5V)

 

GROUND

VSS [1:8]

 

 

 

Ground

SMSC TMC2005-JT

Page 9

Revision 1.1 (07-24-07)

DATASHEET