English

Calibration by user

kg

kg

lb oz kgN

kg

The scale can be calibrated at home if necessary.

You need a standard weight equal to the maximum capacity of your scale.

Switch on the scale.

Wait for 0.0000 display.

Press both keys for 20 seconds with no weight on scale. Display shows 0 at the end of 20 seconds.

Press ON/TARA/OFF.

Display shows CAL 0,

followed by the maximum weight (=6/12/30).

Load scale with maximum weight.

Press ON/TARA/OFF key.

Display shows CAL XX (XX=6/12/30), then 888888.

Then the scale returns to normal weighing mode.

User calibration is only possible in kilos.

Calibration can be stopped by pressing the kg-lb key.

Fault messages

Overload: Do not try to weigh over capacity.

Underload: Switch scale off and on again.

Disconnect power for 10 secs (remove batteries or pull mains lead).

Batteries discharged. Replace 4 x 1.5 V AA size batteries. Zinc/carbon batteries or alkali/manganese batteries as well as nickel/cadmium or nickel/metal hybrid batteries can be used.

Batteries are not charged when the lead is plugged in.

You need a battery charger to charge the batteries.