Soleus Air KC-45H installation manual BeforeCallingService

Models: KC-45H

1 20
Download 20 pages 1.67 Kb
Page 15
Image 15
BeforeCallingService

BeforeCallingService

Manual background WARNING

To reduce the risk of electric shock, personal injury, or death, turn the fan control to the off position and remove the unit plug from the wall outlet before doing any inspection or maintenance work.

The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and suggested remedies are given for each problem.

If the problem cannot be fixed using the suggested remedies, see WHEN SERVICE IS REQUIRED section.

PROBLEM

POSSIBLE CAUSE

SUGGESTED REMEDY

UNIT WILL NOT RUN

No power to unit

Push reset button on power cord.

 

 

Set Fan Control to position other than OFF.

 

 

Make sure plug is firmly seated in outlet.

 

 

Check for blown fuses, tripped circuit breakers.

 

 

 

LITTLE OR NO COOLING

Fresh air/exhaust damper open

Set vent to CLOSED.

LITTLE OR NO HEATING

Obstructed indoor or outdoor airflow

Remove obstruction from indoor grille or outdoor louvers.

(fan and compressor run)

Dirty air filters

Dirty air filter. Clean or replace, as needed.

 

 

Unit undersized for application

Check with dealer to determine proper capacity unit for application.

 

 

 

LITTLE OR NO COOLING

Temperature Control not set properly

For cooling, turn Temperature Control to cooler setting.

LITTLE OR NO HEATING

 

For heating, turn Temperature Control to warmer setting.

(only fan runs)

 

 

NOISY UNIT

Loose front on mounting assembly

Tighten any loose parts.

 

Weak building construction

Provide additional support for unit.

 

Water hitting fan blade

Normal in high humidity. Stop noise by removing drain plug or

 

 

adding condensate drain cup.

 

Unit oversized for application:

Check with dealer to determine proper capacity unit for application.

 

compressor cycles on and off frequently

 

MOUNTING SUPPORT NOT

Storm window frame installed in window

Some models require removal of storm window frame before

INSTALLED

 

installation.

FROST ON INDOOR COIL

Dirty air filter

Clean air filter by vacuuming or washing with water and mild soap.

 

Normal for low outdoor temperatures

Turning Temperature Control to warmer setting reduces occurrence

 

 

and duration of frost.

FROST ON OUTDOOR COIL

Normal for outdoor temperatures at or

Call for service only if unit does not heat room and you have

(heat pump models only)

below 45°F

checked all problems and remedies listed under LITTLE OR NO

 

 

HEATING.

ODORS IN COOLING

Mold, mildew, or algae formation on wet

To reduce algae growth, use algaecide tablet in base pan; remove

 

surfaces

drain plug; add condensate drain cup and hose. Thoroughly clean

 

 

unit.

ODORS IN HEATING

Normal for first time electric heater is

Caused by dust accumulation during unused months.

 

used each season

Odor dissipates quickly with heater use.

 

 

 

 

 

13

Page 15
Image 15
Soleus Air KC-45H installation manual BeforeCallingService