Soleus Air KFHHP-18-OD Installation Services, Precautions on Installation, Important Caution

Models: KFHHP-18-OD KFHHP-18-ID

1 26
Download 26 pages 54.45 Kb
Page 17
Image 17
Installation Services

Installation Services

Precautions on Installation

Important Caution

1.The air-conditioning unit must be installed by professional technicians in accordance with the state and local codes.

2.Contact the local installation and service agency before installation.

3.For relocation of the air conditioner to another position, please contact the local Authorized Service Center.

Basic Requirements for Installation Position

Installation at the following places may cause failure of the air conditioning unit. Please contact installation and service agency if the installation at such places cannot be avoided.

Any environment where the strong heat, steam, flammable or explosive gas exists or the volatile matters are distributed in the air.

Any place close to high-frequency facilities, e.g. welding machine, medical equipment.

A region with saline-sodic soil near the ocean.

A place where the air contains oil (mechanical oil).

A place with sulphide gases (such as sulphur spring).

Any environment with special conditions.

Indoor unit Selection of Installation Position

1.The air inlet and air outlet must be away from obstacles to ensure that airflow can reach every corner of the room.

2.Choose a position where condensation water can be easily discharged and the outdoor unit can be easily connected.

3.Install the unit in a place where the children can not reach.

4.Choose a place where the weight of indoor unit can be withstood and operating noise and vibration are not increased.

5.Ensure sufficient clearance and space for service and maintenance; Ensure the indoor unit is at least 2.3m from the floor.

6.Choose a position at least 3.28 feet from any TV, sound system or other household electric appliances.

7.Choose a place so that the air filter can be easily pulled out.

8.Ensure the installation of indoor unit is in conformity with the requirements of installation dimension drawing.

(◆Precautions on Installation page 17)

Outdoor unit Selection of Installation Position

1.The place where the noise and air flow from the fan will not affect the neighbors, animals or plants.

2.Ensure good ventilation of outdoor unit.

3.No obstacles near the outdoor unit obstructing the air intake and air exhaust of the unit.

4.The installation position shall be able to withstand the weight and vibration of the outdoor unit and ensure safe installation.

5.Select a dry place but not exposed to direct sunshine or strong wind.

6.Ensure that the outdoor unit is installed in compliance with installation dimensions for easy repair and

maintenance. (Important Caution page 17)

7.Height difference of fitting pipes shall be within 16.4 feet and the length of fitting pipe shall be within 32.8 feet.

8.Install the unit in a place where the children can not reach.

9.A place not affecting the public passage or city view.

Electrical Safety Requirements

1.The power supply must be of rated voltage via special circuit for air conditioning. The wire size of power lines shall conform to code.

2.Applicable voltage range: the normal operation range of voltage is 90%110% of rated voltage.

3.Do not pull the power line with force.

-15 -

Page 17
Image 17
Soleus Air KFHHP-18-OD, KFHHP-18-ID Installation Services, Precautions on Installation, Important Caution