◆Specifications and Technical Data

Specifications and Technical Data

 

Model

 

 

KFHHP-18-ID / KFHHP-18-OD

 

 

 

 

 

 

 

 

Function

 

 

Heating and Cooling

 

 

 

 

 

 

 

Cooling capacity(BTU/hr) & (Watts)

18000 / 5300 (1400-6000)

 

 

 

 

 

 

 

Heating capacity(BTU/hr) & (Watts)

20000 / 6000 (1100-7000)

 

 

 

 

 

 

 

 

Rated voltage

 

 

208-230V

 

 

 

 

 

 

 

 

Rated Frequency

 

 

60Hz

 

 

 

 

 

 

 

Cooling/Heating rated current(A)

10.6/10.6

 

 

 

 

 

 

 

 

Cooling/Heating rated power(W)

2440/2440

 

 

 

 

 

 

 

 

Cooling/Heating power input(W)

1350/1800

 

 

 

 

 

 

 

 

 

SEER

 

13.25

 

 

 

 

 

 

 

 

 

EER/COP(W/W)

 

3.93/3.22

 

 

 

 

 

 

 

 

 

HSPF

 

8.5

 

 

 

 

 

 

 

 

Recycling Air Volumem3/h

800

 

Factory Charge 410A (lbs.)*

 

 

R410A 3.9 lbs

 

 

 

 

 

 

 

 

Noise (Indoor/Outdoor) dBA

 

50/57

 

 

 

 

 

 

 

 

Height Differential

Maximum Vertical

 

16.4 ft

 

 

 

 

 

 

Maximum Length

 

32.8 ft

 

 

 

 

 

 

 

 

 

 

Net Weight (Indoor/Outdoor) (lb)

28.7/130.1

 

 

 

 

 

 

 

Dimensions (Indoor/Outdoor)

 

Indoor unit 40.16” × 8.98” ×12.20”

(WxDxH)(inch)

 

 

Outdoor unit37.40” × 13.39” × 26.93”

Connection Pipe:

 

 

 

 

 

Length (ft)

 

 

26.25

 

 

Gas additional charge(oz/ft)

 

 

0.21

 

 

Outer Diameter

 

Liquid Pipe (mm)

 

Φ9.52(5/8”)

 

 

 

Gas Pipe (mm)

 

Φ16(3/8”)

 

 

 

 

 

 

 

 

Max Distance

 

Height (ft)

 

26.25

 

 

 

Length (ft)

 

49.21

 

 

 

 

 

 

 

™

All above are tested and certified to ETL specification. Among them, the cooling capacity, heating

 

capacity and noise level are tested before shipment.

 

 

™

In case of any change in performance parameters, the data provided on nameplate shall prevail.

™

Test the maximum input power under maximum cooling condition (89.6°F /73.4°F, 109.4°F /78.8°F)

 

and maximum heating condition (44.6°F /-, 75.2°F /69.8°F).

™

Working temperature range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor side DB/WB(°F)

Outdoor side DB/WB(°F)

 

 

 

 

 

 

 

 

 

 

Maximum cooling

 

89.6 / 73.4

109.4 / 78.8(T1)

 

 

Minimum cooling

 

69.8 / 59

64.4 / -

 

 

 

Maximum heating

 

80.6 / -

75.2 / 64.4

 

 

 

Minimum heating

 

68 / -

19.4 / 17.6

 

- 4 -