◆Instructions for Use
Principle and Special Functions during Cooling Mode
Principle:
The air conditioner absorbs heat from indoor air and transmits it outdoors for discharge, hence to decrease the indoor ambient temperature. The cooling capacity decreases with the rise of outdoor ambient temperature.
Anti-freeze Function:
If the air conditioner is running under
Principle and Special Functions under Heating Mode
Principle:
*The air conditioner absorbs heat from outdoor air and transmits it indoors for emission, hence to increase the air temperature in the room. The heating capacity decreases with the reduction of the outdoor ambient temperature.
*It takes only a short time for this type of hot air circulating system to increase the indoor temperature.
*Use this air conditioner with other heating equipment if the outdoor temperature is extremely low.
Defrost:
*When the outdoor temperature is low but the humidity is high, the heat exchanger of outdoor unit may freeze after the air conditioner has run for a period of time. This will decrease the heating effect. In this case, auto defrost function will be activated and the heating mode will temporarily stopped for
*Both the indoor fan and outdoor fan will be stopped during auto defrost.
*During defrost, the indicator on indoor unit will blink and steam might flow from the indoor unit. This is caused by quick defrost other than fault.
*Heating mode will automatically resume upon completion of defrost process.
Under heating mode, if the indoor heat exchanger fails to reach a specific temperature under the following conditions, the indoor fan will not be started, so as to avoid blowing of cold air (within 3 minutes):
1. Start of heating mode. | 2. End of auto defrost. | 3. Heating under |
★Conditions that the Air Conditioner will be unable to run normally:
The protection device will be activated within such temperature range as specified below, so that the unit will be shut down.
Heating Mode
Outdoor temperature
over 75.2°F
Outdoor temperature
below 19.4°F
Room temperature
over 80.6°F
Cooling
Mode
Outdoor temperature
over 109.4°F
Room temperature
below 69.8°F
Dehumidify
Mode
Room
temperature
below 64.4°F
If the unit is run for extended periods under high humidify (80% +) condensation will be present at the outlets.
- 5 -