No air blows out from indoor unit.

Trouble-Shooting

Fault

Cause Analysis

 

 

No air blows out from indoor unit.

• When the temperature of indoor heat exchanger is

 

low during heating process, the indoor unit will stop

 

blowing to prevent blowing of cold air (within 3

 

minutes).

 

• Under dehumidify mode, the fan of the indoor unit

 

might be stopped to prevent evaporation of

 

condensing water and inhibit the rise of temperature.

 

 

Moisture exists on outlet grill.

• If the unit is run for extended periods under high

 

humidity condensation will be present at the outlets.

 

 