Compressor Indicator

Sleep Mode (This mode can only be selected when using the Remote control )

1)To set Sleep mode, make sure the unit is in Air Conditioner mode.

2)Press the SLEEP Button on the remote control. The “ Emergency Condensate Holding Tank ” icon appears on the control panel display.

3)When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.

4)When in Air Conditioner mode, the temperature setting will gradually increase to 2°F above the original set temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.

5)When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.

Compressor Indicator

 

 

 

 

The “

 

 

 

” icon will light up on the control panel display when the compressor turns on. The “

 

 

 

” icon

 

 

 

 

 

 

will turn off when the compressor shuts off.

 

 

 

 

Emergency Condensate Holding Tank

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut

off and the “ Manual background ” will appear on the control panel display. To empty the condensate tank, pull the drain plug at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the water coming out of the condensate tank. Once the condensate tank is drained, the unit will begin working within a few minutes. The emergency condensate tank is approximately 1.5 Liters of water. Another option is to purchase a small hose from a hardware store that can fit around the 5/8” drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage. It is not advised to use continuous drainage when the

room temperature is higher than 90°F .

13

Page 13
Image 13
Soleus Air PE3-12R-03 manual Compressor Indicator, Emergency Condensate Holding Tank

FAQ

How do I set the Sleep Mode?

To set Sleep mode, make sure the unit is in Air Conditioner mode and press the SLEEP Button on the remote control. The fan will run on low to minimize noise, and the temperature setting will gradually increase for 6 hours before returning to the set temperature.

What does the Compressor Indicator mean?

The compressor indicator lights up when the compressor turns on and turns off when the compressor shuts off.

How do I handle the Emergency Condensate Holding Tank?

If the unit is unable to evaporate moisture fast enough, the water accumulates in the emergency condensate tank. To empty the tank, pull the drain plug at the bottom back of the unit, or use a small hose for continuous drainage.