ELECTRICAL REQUIREMENTS

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Power Supply Cord

NEMA 6-20P

Recommended Ground Method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus- tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

To contact a qualified electrician

To assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from: National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

LCDI Power Cord and Plug - NEMA 6-20P

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de- energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

1.Plug power cord into a wall outlet, the power light will turn on.

2.Press the TEST Button, the circuit should trip and cut all power to the air conditioner. The power light will turn off.

3.Press the RESET button for use. The power light will turn back on.

If a test is performed and the indicator light remains ON prior to pressing RESET, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Con- tact Customer Service for troubleshooting recommendations.

3

Page 4
Image 4
Soleus Air SG-TTW-12HC manual Electrical Requirements, Nema 6-20P

SG-TTW-12HC specifications

The Soleus Air SG-TTW-12HC is a versatile and efficient window air conditioning unit designed to provide optimal comfort in residential spaces. With a focus on both functionality and energy efficiency, this unit is ideal for cooling and heating small to medium-sized rooms. It boasts a wide array of features that cater to varied climate needs and user preferences.

One of the standout characteristics of the SG-TTW-12HC is its dual functionality. It operates as an air conditioner during hot summer months and transitions seamlessly into a heat pump during cooler seasons. This feature ensures year-round climate control, making it a perfect solution for regions with fluctuating temperatures.

With a cooling capacity of 12,000 BTUs, the SG-TTW-12HC is capable of cooling spaces up to 550 square feet effectively. Its powerful compressor and design allow for rapid temperature adjustments, ensuring that the room reaches desired comfort levels in minimal time. Additionally, the unit operates quietly, maintaining a noise level of around 53 decibels, which is comparable to the hum of a refrigerator, thus making it suitable for bedrooms and living areas.

The technology integrated into the SG-TTW-12HC emphasizes energy efficiency. It is designed with an Energy Efficiency Ratio (EER) that meets or exceeds industry standards, resulting in lower electricity bills. This air conditioner also features a programmable thermostat, allowing users to set specific temperature targets and schedules, further enhancing energy conservation.

Another notable feature is the unit's advanced filtration system. It includes a washable and reusable filter that effectively captures dust, allergens, and other particles, contributing to improved indoor air quality. The filter is easy to access and clean, ensuring hassle-free maintenance for users.

Installation of the Soleus Air SG-TTW-12HC is made straightforward with its window-mounted design, making it a compact and space-saving option for apartments or homes with limited space. Additionally, the unit comes equipped with a remote control, providing convenience for users to adjust settings from across the room.

In summary, the Soleus Air SG-TTW-12HC is a robust window air conditioning unit featuring cooling and heating capabilities, ensuring comfort throughout the year. Its energy-efficient design, quiet operation, advanced filtration system, and user-friendly controls make it a reliable choice for anyone looking to enhance their living environment.