Solid State Logic 82S6XL010D Distortion Null, VCA Gain Adjust, Input Measure Adjust, Input Adjust

Models: 82S6XL010D

1 18
Download 18 pages 47.08 Kb
Page 16
Image 16

XLogic Multichannel Compressor Owner’s Manual

Distortion Null

Equipment Required:

Calibrated audio oscillator, audio distortion analyser and oscilloscope

Test Signal:

1kHz sinewave at +24dBu

 

 

Input and Output:

Oscillator to the Input of the channel being tested, Output to the distortion

 

analyser. Use the oscilloscope to monitor the measured signal.

Adjustment:

1. Connect the +ve input of the analyser to the test point as shown below and

 

connect the –ve input of the analyser to a 0VA test point. Note that the circuitry

 

at this point is balanced and so there are two measurements and two adjustments

 

per channel. Adjust for minimum THD (< 0.007%).

 

Input

Measure

Adjust

 

Left (+ve)

TP31

VR24

 

Left (–ve)

TP32

VR23

 

Right (+ve)

TP29

VR22

 

Right (–ve)

TP30

VR21

 

Centre (+ve)

TP27

VR20

 

Centre (–ve)

TP28

VR19

 

LFE (+ve)

TP21

VR14

 

LFE (–ve)

TP22

VR13

 

Left Sur (+ve)

TP23

VR16

 

Left Surr (–ve)

TP24

VR15

 

Right Surr (+ve)

TP25

VR18

 

Right Surr (–ve)

TP26

VR17

2.Finally, re-connect the analyser to each output in turn and adjust the +ve distortion null to see if any reduction in THD can be achieved.

VCA Gain Adjust

Equipment Required:

 

Calibrated audio oscillator, audio level meter, oscilloscope and a (digital) DC

 

 

voltmeter

Test Signal:

 

1kHz sinewave at +20dBu

Input and Output:

 

Oscillator to the Input of the channel being tested, Output to the level meter. Use

 

 

the oscilloscope to monitor the measured signal.

Unit Setup:

1.

Switch the Master Fader IN.

 

2.

Using the DVM, measure TP5 on the upper card (629607) and adjust the front

 

 

panel Master Fader for –2.00V ±1mV (which equates to 40dB attenuation).

Adjustment:

1.

Connect the audio level meter to each output in turn. Measure each channel,

 

 

adjusting the appropriate preset for –20dBu ±0.1dB (which equates to 40dB of

 

 

attenuation).

Input

Adjust

Left

VR30

Right

VR29

Centre

VR34

LFE

VR36

Left Surround

VR27

Right Surround

VR28