![Front](/images/new-backgrounds/17107/1710725x1.webp)
SO N A M P ® ASAP3D SE ST E R E O PO W E R AM P L I F I E R
Appendix 1: Changing the Mono Variable Output to a Fixed Output Level
The MONO VAR OUT is
1.Unplug the amplifier’s power cord from the Power Cord Connection on the back of the amplifier.
2.Remove the 8 screws (4 on top and 2 on each side) that secure the amp’s chassis cover.
3.Locate the MONO OUT section on the circuit board (see Figure 27).
4.Remove the jumper from the center pin and the “V” (variable) pin and
5.Replace the amplifier’s chassis cover and screws, and plug the power cord back into the Power Cord Connection.
Front |
Panel |
MONO OUT |
Jumper |
FIGURE 27: MONO OUT JUMPER LOCATION |
Jumper | Jumper |
Variable | Fixed |
FIGURE 28: CHANGING THE JUMPER FROM FIXED TO VARIABLE |
Appendix 2: IR Command List
The following ASAP3D SE functions can be controlled via IR:
• Amplifier ON (Local source active) | • Volume 0 (Jump to 0) |
• Amplifier OFF (House source active) | • Volume 20 (Jump to 20) |
• Mute ON | • Volume 40 (Jump to 40) |
• Mute OFF | • Volume 60 (Jump to 60) |
• Mute Toggle ON/OFF | • Volume 80 (Jump to 80) |
• Volume | • Volume 100 (Jump to 100) |
• Volume +1 (Up one step) | • BBE ON |
• Volume | • BBE OFF |
• Volume +3 (Up three steps) | • BBE Toggle ON/OFF |
• Volume |
|
• Volume +5 (Up five steps) |
|
13